富二代破解版app官方入口

您好!歡迎光臨冷水機源頭廠家,我們竭誠為您服務!
熱門關健詞:
?

內蒙古自治區水冷式冷水機系統的檢查工作怎么做(1)

2023-12-09

2、膨脹閥的工作原理:
膨脹閥(fa)(fa)通(tong)過(guo)感溫包(bao)感受蒸(zheng)發器(qi)出(chu)口(kou)端(duan)過(guo)熱(re)度的(de)變化,導(dao)致感溫系統(tong)內(感溫系統(tong)是(shi)由感溫包(bao)、毛細管、傳(chuan)(chuan)動(dong)膜(mo)片(pian)和傳(chuan)(chuan)動(dong)波(bo)紋(wen)管這幾(ji)種互相連通(tong)的(de)零件所構成(cheng)的(de)密閉系統(tong))充(chong)注(zhu)物質(zhi)產生壓力變化、并作(zuo)用于傳(chuan)(chuan)動(dong)膜(mo)片(pian)上(shang)(shang).促使(shi)膜(mo)片(pian)形成(cheng)上(shang)(shang)下(xia)(xia)位移(yi),再通(tong)過(guo)傳(chuan)(chuan)動(dong)片(pian)將(jiang)此(ci)力傳(chuan)(chuan)遞(di)給(gei)傳(chuan)(chuan)動(dong)桿而推(tui)動(dong)閥(fa)(fa)針上(shang)(shang)下(xia)(xia)移(yi)動(dong),使(shi)閥(fa)(fa)門關小(xiao)或開大,起到降壓節(jie)流作(zuo)用和自動(dong)調節(jie)蒸(zheng)發器(qi)的(de)制(zhi)冷劑供(gong)給(gei)量并保持蒸(zheng)發器(qi)出(chu)口(kou)端(duan)具(ju)有一定(ding)過(guo)熱(re)度,得以保證(zheng)蒸(zheng)發器(qi)傳(chuan)(chuan)熱(re)面積的(de)充(chong)分利用,以及減少(shao)液擊沖缸(gang)現象的(de)發生。

低溫制冷機

水(shui)冷式工(gong)(gong)業(ye)工(gong)(gong)業(ye)制冷機(ji)組(zu)是本(ben)標準規定的(de)(de)一種環保節(jie)能設備。冷卻(que)(que)水(shui)溫(wen)度可根據用(yong)戶需要自動調節(jie)。長(chang)期應用(yong)可節(jie)約水(shui)資(zi)源。水(shui)冷式工(gong)(gong)業(ye)工(gong)(gong)業(ye)制冷機(ji)組(zu)在(zai)正(zheng)常運(yun)行過程(cheng)中,不可避免(mian)的(de)(de)會受到污垢或(huo)其他雜(za)質的(de)(de)影響(xiang),影響(xiang)冷卻(que)(que)效(xiao)果。因此,為(wei)了更(geng)好地延長(chang)主工(gong)(gong)業(ye)制冷機(ji)的(de)(de)使用(yong)壽命,達(da)到更(geng)好的(de)(de)冷卻(que)(que)效(xiao)果,對(dui)水(shui)冷工(gong)(gong)業(ye)工(gong)(gong)業(ye)制冷機(ji)的(de)(de)水(shui)系統應按時進行檢查(cha),以保證工(gong)(gong)業(ye)制冷機(ji)的(de)(de)運(yun)行質量,提高工(gong)(gong)作(zuo)效(xiao)率。

制冷機組

如何檢查水冷式工(gong)業工(gong)業制冷機的水系統?

工業制冷設備

冷水機廣泛地應用在各個領域:
塑(su)(su)(su)膠模(mo)(mo)具(ju)行業:塑(su)(su)(su)膠在塑(su)(su)(su)模(mo)(mo)生(sheng)產中,模(mo)(mo)具(ju)會產生(sheng)高溫,高溫模(mo)(mo)具(ju)下脫(tuo)膜的(de)塑(su)(su)(su)料(liao)制(zhi)(zhi)品(pin)表面(mian)(mian)(mian)容易產生(sheng)表面(mian)(mian)(mian)紋痕(hen)。冷(leng)水(shui)(shui)機(ji)的(de)使用,可(ke)將模(mo)(mo)具(ju)迅速冷(leng)卻,減少塑(su)(su)(su)料(liao)制(zhi)(zhi)品(pin)表面(mian)(mian)(mian)紋痕(hen)和內應力,使產品(pin)不縮水(shui)(shui)、不變形,便(bian)于塑(su)(su)(su)料(liao)制(zhi)(zhi)品(pin)的(de)脫(tuo)模(mo)(mo),使得塑(su)(su)(su)料(liao)制(zhi)(zhi)品(pin)表面(mian)(mian)(mian)更加(jia)光(guang)潔(jie)無脫(tuo)模(mo)(mo)紋痕(hen),加(jia)速產品(pin)定型(xing),不僅大大地提高了機(ji)器(qi)的(de)生(sheng)產效率,產品(pin)的(de)質量也得到大地提高。

1. 檢(jian)查(cha)水(shui)冷(leng)(leng)工業工業制冷(leng)(leng)機(ji)的(de)冷(leng)(leng)卻水(shui)、冷(leng)(leng)凍水(shui)管(guan)(guan)是否沖洗干凈(jing),與外界連(lian)接的(de)冷(leng)(leng)卻塔、水(shui)池等處是否有雜(za)質(zhi)。確(que)保存儲過程中無雜(za)質(zhi)、雜(za)物(wu)。檢(jian)查(cha)水(shui)側氣壓計(ji)與溫(wen)度(du)計(ji)的(de)連(lian)接是否正確(que)。氣壓表(biao)應隨水(shui)管(guan)(guan)垂直90°安裝。溫(wen)度(du)計(ji)的(de)安裝應確(que)保其感溫(wen)探頭插入(ru)水(shui)管(guan)(guan)中。

水冷式冷水機

制冷螺桿機

2. 檢(jian)查(cha)水(shui)冷(leng)(leng)(leng)工業工業制冷(leng)(leng)(leng)機冷(leng)(leng)(leng)凍/冷(leng)(leng)(leng)卻水(shui)出口側流量(liang)開關(guan)(guan)安(an)裝是(shi)(shi)否正(zheng)確(que)(que),流量(liang)開關(guan)(guan)與控制箱接線是(shi)(shi)否正(zheng)確(que)(que)。啟動冷(leng)(leng)(leng)凍水(shui)、冷(leng)(leng)(leng)卻水(shui)離(li)(li)心(xin)泵(beng),檢(jian)查(cha)離(li)(li)心(xin)泵(beng)旋轉(zhuan)方向。離(li)(li)心(xin)水(shui)泵(beng)的(de)正(zheng)確(que)(que)旋轉(zhuan)方向應為(wei)順時針(zhen),否則請重新檢(jian)查(cha)離(li)(li)心(xin)水(shui)泵(beng)的(de)接線方法。

3.啟動(dong)水(shui)(shui)(shui)(shui)冷(leng)式工業工業制冷(leng)機的(de)(de)冷(leng)凍(dong)水(shui)(shui)(shui)(shui)和冷(leng)卻水(shui)(shui)(shui)(shui)離心泵(beng)(beng),使水(shui)(shui)(shui)(shui)流(liu)循環。檢查水(shui)(shui)(shui)(shui)管是否(fou)漏水(shui)(shui)(shui)(shui),是否(fou)有(you)明顯(xian)漏水(shui)(shui)(shui)(shui)、滲水(shui)(shui)(shui)(shui)現(xian)象。冷(leng)凍(dong)水(shui)(shui)(shui)(shui)離心泵(beng)(beng)、冷(leng)卻水(shui)(shui)(shui)(shui)離心泵(beng)(beng)試運行。檢查水(shui)(shui)(shui)(shui)壓(ya)是否(fou)穩(wen)定(ding)。觀察離心水(shui)(shui)(shui)(shui)泵(beng)(beng)進、出(chu)口(kou)氣壓(ya)計(ji)。當水(shui)(shui)(shui)(shui)壓(ya)穩(wen)定(ding)時,氣壓(ya)計(ji)的(de)(de)讀(du)數和進出(chu)口(kou)壓(ya)力差值變化不大。檢查離心水(shui)(shui)(shui)(shui)泵(beng)(beng)的(de)(de)工作電(dian)流(liu)是否(fou)在(zai)其額定(ding)工作電(dian)流(liu)范圍內。如果離額定(ding)值太遠(yuan),請(qing)檢查系(xi)統電(dian)阻是否(fou)過大。請(qing)解決系(xi)統異常(chang),直到實際運行電(dian)流(liu)滿足要求。

制冷機

4. 檢查水冷(leng)(leng)工業工業制冷(leng)(leng)機(ji)冷(leng)(leng)卻塔/膨脹(zhang)罐補水裝置(zhi)是否(fou)通暢,水系統自動排(pai)(pai)氣(qi)閥(fa)(fa)是否(fou)能自動排(pai)(pai)風(feng)。如(ru)果是手動排(pai)(pai)氣(qi)閥(fa)(fa),請打開冷(leng)(leng)凍水管路(lu)和冷(leng)(leng)卻水管路(lu)的排(pai)(pai)氣(qi)閥(fa)(fa),將(jiang)氣(qi)體(ti)排(pai)(pai)出(chu)。

5. 調節(jie)水流,檢查(cha)通(tong)過蒸發器(qi)、冷(leng)凝器(qi)的(de)(de)水壓降是否(fou)滿足工(gong)業制(zhi)冷(leng)機(ji)正常(chang)運(yun)行的(de)(de)要求。即工(gong)業制(zhi)冷(leng)機(ji)的(de)(de)冷(leng)凍水和冷(leng)卻水的(de)(de)進出口壓力不小于(yu)0.2MPa。檢查(cha)并確保水冷(leng)工(gong)業工(gong)業制(zhi)冷(leng)機(ji)冷(leng)卻塔風機(ji)等設(she)施運(yun)行正常(chang),無異常(chang)噪(zao)聲(sheng)。檢查(cha)風機(ji)皮帶(dai)松(song)緊是否(fou)合適(shi),確保風機(ji)與電機(ji)之間的(de)(de)連接(jie)皮帶(dai)不打滑(hua),運(yun)轉時無異常(chang)噪(zao)音。